{"product_id":"3dresyn-od-clear-cv1-mf-bio-monomer-free-ceramic-filled-dental-coating-photopolymer-for-professional-laboratory-workflows","title":"3Dresyn OD-Clear CV1 MF Bio – Monomer-Free Ceramic-Filled Dental Coating Photopolymer for Professional Laboratory Workflows","description":"\u003ch4\u003eProduct description\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e3Dresyn® OD-Clear CV1 MF Bio\u003c\/strong\u003e is a monomer-free, ceramic-filled transparent dental coating formulation developed for professional laboratory surface finishing workflows of dental components requiring enhanced abrasion resistance, optical clarity and controlled surface performance.\u003c\/p\u003e\n\u003cp\u003eThe monomer-free formulation architecture is designed to support reduced residual monomer content when properly cured and post-processed, while maintaining transparent surface performance under validated laboratory conditions.\u003c\/p\u003e\n\n\u003ch4\u003eApplication framework\u003c\/h4\u003e\n\u003cp\u003eDesigned for application within controlled professional laboratory environments on properly prepared dental substrates. Final suitability, validation and regulatory compliance of coated components must be assessed by the user according to the specific device design, workflow validation and applicable regulatory requirements.\u003c\/p\u003e\n\n\u003ch4\u003eTypical laboratory applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional laboratory surface finishing of dental components\u003c\/li\u003e\n\u003cli\u003eTransparent protective coating of dental substrates\u003c\/li\u003e\n\u003cli\u003eDental components requiring enhanced abrasion resistance\u003c\/li\u003e\n\u003cli\u003eDental components requiring optical clarity and controlled surface performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eMeasured mechanical properties\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTensile strength: \u0026gt; 50 MPa (ISO 527-1 \/ ISO 527-2)\u003c\/li\u003e\n\u003cli\u003eFlexural strength: \u0026gt; 90 MPa (ISO 178)\u003c\/li\u003e\n\u003cli\u003eYoung’s modulus: 2500–3000 MPa (ISO 527-1 \/ ISO 527-2)\u003c\/li\u003e\n\u003cli\u003eElongation at break: \u0026lt; 5 % (ISO 527)\u003c\/li\u003e\n\u003cli\u003eShore hardness: D85–90 (ISO 868)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eFunctional performance characteristics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh transparency and non-yellowing behavior\u003c\/li\u003e\n\u003cli\u003eEnhanced abrasion and wear resistance due to ceramic filler content\u003c\/li\u003e\n\u003cli\u003eStrong adhesion to properly prepared polymeric dental substrates under validated processing conditions\u003c\/li\u003e\n\u003cli\u003eFast UV\/visible light curing within 200–420 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eContains approximately 5% nano-ceramic fillers contributing to enhanced wear resistance and surface durability under validated curing conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptical and surface performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransparent coating appearance\u003c\/li\u003e\n\u003cli\u003eHigh optical clarity\u003c\/li\u003e\n\u003cli\u003eControlled surface performance for dental coating workflows\u003c\/li\u003e\n\u003cli\u003eNon-yellowing behavior\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eThermal, pressure and chemical resistance\u003c\/h4\u003e\n\u003cp\u003eSurface performance, abrasion resistance and coating durability depend on validated substrate preparation, curing conditions and laboratory workflow.\u003c\/p\u003e\n\n\u003ch4\u003eProcessing and handling performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStrong adhesion to properly prepared polymeric dental substrates under validated processing conditions\u003c\/li\u003e\n\u003cli\u003eFast UV\/visible light curing within 200–420 nm wavelength range\u003c\/li\u003e\n\u003cli\u003eOrgano-tin free formulation\u003c\/li\u003e\n\u003cli\u003eReduced residual monomer content when properly cured and post-processed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWater sorption and solubility\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWater absorption: \u0026lt; 15 µg\/mm³\u003c\/li\u003e\n\u003cli\u003eWater sorption: ≤ 32 µg\/mm³ (reference methodology aligned with ISO 20795-1)\u003c\/li\u003e\n\u003cli\u003eWater solubility: ≤ 1.6 µg\/mm³ (reference methodology aligned with ISO 20795-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eChemical safety indicators\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMonomer-free formulation\u003c\/li\u003e\n\u003cli\u003eReduced residual monomer content when properly cured and post-processed\u003c\/li\u003e\n\u003cli\u003eOrgano-tin free formulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eBiocompatibility framework\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBiocompatibility-related evaluations may be conducted according to relevant ISO 10993 methodologies depending on formulation version and validated processing protocol\u003c\/li\u003e\n\u003cli\u003eAssessment and certification of any final medical device incorporating this coating remain the responsibility of the legal manufacturer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eTesting \u0026amp; processing disclaimer\u003c\/h4\u003e\n\u003cp\u003eMaterial properties and coating performance may vary depending on substrate type, surface preparation, curing conditions and laboratory workflow validation. Reported information is provided for reference only.\u003c\/p\u003e\n\n\u003ch4\u003ePrinting \u0026amp; processing guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eApplication type: professional laboratory coating workflow\u003c\/li\u003e\n\u003cli\u003eCuring wavelength range: 200–420 nm\u003c\/li\u003e\n\u003cli\u003eApplication substrate: properly prepared dental substrates\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eWhy choose 3Dresyn® OD-Clear CV1 MF Bio\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMonomer-free coating formulation for improved chemical safety positioning\u003c\/li\u003e\n\u003cli\u003eTransparent coating with high optical clarity\u003c\/li\u003e\n\u003cli\u003eEnhanced abrasion and wear resistance from ceramic filler content\u003c\/li\u003e\n\u003cli\u003eStrong adhesion to properly prepared polymeric dental substrates\u003c\/li\u003e\n\u003cli\u003eReduced yellowing with controlled surface performance\u003c\/li\u003e\n\u003cli\u003eOrgano-tin free formulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eRegulatory \u0026amp; legal notice\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThis material is supplied as a professional manufacturing material for laboratory workflows. It is not marketed as a finished medical device.\u003c\/strong\u003e The regulatory classification and compliance of any final dental device manufactured or coated using this material remain the sole responsibility of the legal manufacturer in accordance with applicable regulations, including Regulation (EU) 2017\/745.\u003c\/p\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(0,0,0,.14); padding: 16px; border-radius: 18px; background: #fafafa; margin-top: 24px; margin-bottom: 12px;\"\u003e\n\u003cstrong\u003ePart of the 3Dresyns® Technical Documentation System\u003c\/strong\u003e\n\u003cp style=\"margin: .5rem 0 0 0;\"\u003eThis technical datasheet should be used together with the relevant processing, calibration, safety and workflow documentation available in the 3Dresyns® Resources section.\u003c\/p\u003e\n\u003cp style=\"margin: .6rem 0 0 0;\"\u003e\u003ca href=\"https:\/\/www.3dresyns.com\/pages\/resources\"\u003eAccess the 3Dresyns® Technical Resources (IFU, calibration, CRT, post-processing and troubleshooting)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eDocument reference: TDS-3DRESYN-OD-CLEAR-CV1-MF-BIO-EN | Version: 1.0 | Last updated: March 2026\u003c\/p\u003e\n","brand":"3Dresyns","offers":[{"title":"500 grams","offer_id":48311821762894,"sku":"P20888","price":416.5,"currency_code":"EUR","in_stock":true},{"title":"1000 grams","offer_id":48311749574990,"sku":"P20889","price":714.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0282\/5616\/products\/Dental-bio2-clear_9ac8b6f5-da73-45d0-8c9f-c8b692a035fc.png?v=1701293068","url":"https:\/\/www.3dresyns.com\/en-de\/products\/3dresyn-od-clear-cv1-mf-bio-monomer-free-ceramic-filled-dental-coating-photopolymer-for-professional-laboratory-workflows","provider":"3Dresyns","version":"1.0","type":"link"}