{"product_id":"3dresyn-od-clear-t-amp-c-tough-amp-comfortable-photopolymer-for-professional-dental-guard-splint-laboratory-workflows","title":"3Dresyn OD-Clear T\u0026C Tough \u0026 Comfortable – Photopolymer for Professional Dental Guard \u0026 Splint Laboratory Workflows","description":"\u003ch4\u003eProduct description\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e3Dresyn® OD-Clear T\u0026amp;C\u003c\/strong\u003e is an advanced photopolymer engineered for the fabrication of dental protection appliances such as night guards and occlusal splints.\u003c\/p\u003e\n\u003cp\u003eThe material provides a balanced combination of toughness, comfort and controlled flexibility under load, enabling durable performance in cyclic mechanical environments.\u003c\/p\u003e\n\u003cp\u003eThe formulation is based on 4D Shape Memory Polymer (SMP) architecture, supporting shape recovery behaviour and stable mechanical response depending on geometry, thickness and processing conditions.\u003c\/p\u003e\n\u003cp\u003eIt is available in LV (lower viscosity) and HV (higher mechanical performance) versions for compatibility across SLA, DLP and LCD systems.\u003c\/p\u003e\n\u003ch4\u003eApplication framework\u003c\/h4\u003e\n\u003cp\u003eIntended for professional use in vat photopolymerization (SLA, DLP and LCD) additive manufacturing for dental laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eFinal suitability of printed parts must be validated by the user according to the specific application, processing conditions and applicable regulatory requirements.\u003c\/p\u003e\n\u003ch4\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNight guards and occlusal splints\u003c\/li\u003e\n\u003cli\u003eDental protection appliances for bruxism and clenching\u003c\/li\u003e\n\u003cli\u003eCustom dental protective devices requiring resilience and comfort\u003c\/li\u003e\n\u003cli\u003eFlexible dental components and positioning elements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasured mechanical properties\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTensile strength: \u0026lt;40 MPa (ISO 527-1 \/ ISO 527-2)\u003c\/li\u003e\n\u003cli\u003eFlexural strength: \u0026lt;40 MPa (ISO 178 \/ ISO 20795-1 reference framework)\u003c\/li\u003e\n\u003cli\u003eYoung’s modulus: ~600–1200 MPa (ISO 527-1 \/ ISO 527-2)\u003c\/li\u003e\n\u003cli\u003eElongation at break: \u0026lt;30% (ISO 527-1 \/ ISO 527-2)\u003c\/li\u003e\n\u003cli\u003eShore hardness: D60–70 (ISO 868)\u003c\/li\u003e\n\u003cli\u003eImpact resistance (Notched Izod): \u0026lt;70 J\/m (ISO 180)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasured physical properties\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOptical behaviour: excellent clarity and non-yellowing\u003c\/li\u003e\n\u003cli\u003eWater solubility: ≤1.6 µg\/mm³ (ISO 20795-1 reference framework)\u003c\/li\u003e\n\u003cli\u003eWater sorption (ULWA): ≤32 µg\/mm³ (ISO 20795-1 reference framework)\u003c\/li\u003e\n\u003cli\u003eResidual monomer: \u0026lt;0.1% when properly cured and post-processed\u003c\/li\u003e\n\u003cli\u003eShrinkage: very low\u003c\/li\u003e\n\u003cli\u003eViscosity of HV version: \u0026lt;8000 mPas at 23°C ± 2°C (ISO 3219)\u003c\/li\u003e\n\u003cli\u003eViscosity of LV version: \u0026lt;4000 mPas at 23°C ± 2°C (ISO 3219)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFunctional performance characteristics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eControlled flexibility under load for improved comfort\u003c\/li\u003e\n\u003cli\u003eShape recovery behaviour under cyclic stress\u003c\/li\u003e\n\u003cli\u003eBalanced stiffness for protection and wear resistance\u003c\/li\u003e\n\u003cli\u003eHigh durability under repeated mechanical loading\u003c\/li\u003e\n\u003cli\u003e4D Shape Memory Polymer (SMP) architecture\u003c\/li\u003e\n\u003cli\u003eShape memory activation via thermal stimulus\u003c\/li\u003e\n\u003cli\u003eAvailable in rigid and flexible performance configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProcessing and handling performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrinting technologies: SLA, DLP and LCD\u003c\/li\u003e\n\u003cli\u003eWavelength range: 385–405 nm\u003c\/li\u003e\n\u003cli\u003eCompatible with open-parameter vat photopolymerization systems\u003c\/li\u003e\n\u003cli\u003eLV version optimized for printing below ~25 °C or without heated vats\u003c\/li\u003e\n\u003cli\u003eHV version optimized for printing above ~25 °C and enhanced mechanical performance\u003c\/li\u003e\n\u003cli\u003eSuitable for thin structures down to 0.2–0.3 mm\u003c\/li\u003e\n\u003cli\u003eFollow 3Dresyns IFU for exposure, washing and post-curing\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.3dresyns.com\/pages\/ifu-for-100-clarity-transparency-without-any-haziness-or-whitish-finishing\"\u003eIFU for 100% clarity \u0026amp; transparency\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eChemical and safety characteristics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOrgano-tin free formulation\u003c\/li\u003e\n\u003cli\u003eUltra low water absorption (ULWA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBiocompatibility framework\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBiocompatibility-related testing may be performed under controlled laboratory conditions depending on formulation and validated workflow\u003c\/li\u003e\n\u003cli\u003eEvaluation frameworks may include ISO 20795 and ISO 10993 methodologies\u003c\/li\u003e\n\u003cli\u003eManufacturing aligned with ISO 13485 quality management systems\u003c\/li\u003e\n\u003cli\u003eFinal biological performance depends on validated processing workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTesting \u0026amp; processing disclaimer\u003c\/h4\u003e\n\u003cp\u003eMaterial properties are measured on printed and post-processed specimens and may vary depending on material version, printer type, printing parameters, build orientation, post-curing conditions and workflow validation. Reported values are indicative and provided for reference only.\u003c\/p\u003e\n\u003ch4\u003eDisclaimer\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThis material is supplied as a professional manufacturing material for dental laboratory workflows and is not marketed as a finished medical device.\u003c\/strong\u003e The regulatory classification, conformity assessment and validation of any final dental appliance manufactured using this material remain the sole responsibility of the legal manufacturer in accordance with applicable regulations, including Regulation (EU) 2017\/745.\u003c\/p\u003e\n\u003cdiv style=\"border: 1px solid rgba(0,0,0,.14); padding: 16px; border-radius: 18px; background: #fafafa; margin-top: 24px; margin-bottom: 12px;\"\u003e\n\u003cstrong\u003ePart of the 3Dresyns® Technical Documentation System\u003c\/strong\u003e\n\u003cp style=\"margin: .5rem 0 0 0;\"\u003eThis technical datasheet should be used together with the relevant processing, calibration, safety and workflow documentation available in the 3Dresyns® Resources section.\u003c\/p\u003e\n\u003cp style=\"margin: .6rem 0 0 0;\"\u003e\u003ca href=\"https:\/\/www.3dresyns.com\/pages\/resources\"\u003eAccess the 3Dresyns® Technical Resources (IFU, calibration, CRT, post-processing and troubleshooting)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 0.9em; opacity: 0.8;\"\u003eDocument reference: TDS-OD-T\u0026amp;C-EN | Version: 2.0 | Last updated: March 2026\u003c\/p\u003e","brand":"3Dresyns","offers":[{"title":"Rigid version \/ 1000 grams","offer_id":41377512292526,"sku":"P20237","price":357.0,"currency_code":"EUR","in_stock":true},{"title":"Flexible version \/ 1000 grams","offer_id":42101392179374,"sku":"P20238","price":357.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0282\/5616\/products\/clear-aligner.jpg?v=1632825588","url":"https:\/\/www.3dresyns.com\/en-de\/products\/3dresyn-od-clear-t-amp-c-tough-amp-comfortable-photopolymer-for-professional-dental-guard-splint-laboratory-workflows","provider":"3Dresyns","version":"1.0","type":"link"}