Technical Bulletin — Cure Kinetics & Jacobs Working Curve (405 nm)
Technical Scope
This technical bulletin provides the quantitative basis for the applied engineering interpretation of FT1 and LB1 Bio fine-tuning strategies.
Applied Engineering Analysis – FT1 & LB1 Bio (405 nm)
Material system: 3Dresyn PEEK-like with FT1 and LB1 Bio fine-tuning additives.
Optical conditions: 405 nm; irradiance levels of 2.2, 4, 6, and 8 mW/cm².
Methodology: Cure-depth mapping, dose-based normalization, and Jacobs working-curve modeling.
How This Bulletin Fits Within the 3Dresyns Framework
- Fine-tuning additives: printing speed, resolution, and dimensional control
- 3Dresyns calibration files
- Resolution vs. precision vs. dimensional accuracy
- Photo-accelerants and photoreactivity modifiers
- Light blockers and resolution modifiers
Engineering Interpretation
- FT1 (photo-accelerant): shifts cure onset toward lower dose by reducing the apparent critical exposure (Ec). It is used primarily to increase printing speed.
- LB1 Bio (resolution modifier): improves optical confinement, reducing light bleeding and overcure. It supports higher XY detail and improved dimensional stability.
- Dose control is critical: Dose (mJ/cm²) = irradiance (mW/cm²) × exposure time (s). Real irradiance at 405 nm should be verified for reproducible results.
Cure Depth vs. Time (405 nm)
Cure Depth vs. Time at 2.2 mW/cm² (405 nm)
Cure Depth vs. Time at 4 mW/cm² (405 nm)
Cure Depth vs. Time at 6 mW/cm² (405 nm)
Cure Depth vs. Time at 8 mW/cm² (405 nm)
Cure Depth vs. Time for Different FT1 and LB1 Bio Concentrations
Dose-Based Analysis (Power–Time Reciprocity)
Dose-based normalization can support first-order cross-printer comparison under matched optical and kinetic conditions.
Dose (mJ/cm²) = irradiance (mW/cm²) × exposure time (s)
Jacobs Working Curve (Ec and Dp Extraction)
Model: Cd = Dp · ln(E / Ec)
Extracted Parameters (Updated Dataset)
| Formulation | Ec (mJ/cm²) | Dp (µm) | R² |
|---|---|---|---|
| 2% FT1 + 10% LB1 Bio | 19.09 | 148.25 | 0.669 |
| 4% FT1 + 5% LB1 Bio | 19.96 | 190.21 | 0.813 |
| 2% FT1 + 5% LB1 Bio | 23.23 | 184.20 | 0.803 |
Note: These working-curve fits are intended for engineering comparison. Fit quality depends on formulation behavior and the tested dose window.
Validation and Calibration
To translate cure kinetics into real-world dimensional performance, validate the material using calibration geometry and consistent post-processing conditions.
- 3Dresyns calibration files
- Download 3Dtest1 calibration STL file
- Download 3Dtest2 calibration STL file
Technical support: info@3dresyns.com