Two-Photon Polymerization (2PP) Calibration & Process Map
Purpose & scope. This section guides a quick and a full calibration for 2PP with 3Dresyns resins: defining a robust operating window, documenting resolution, and dimensional accuracy at each condition.
Equipment & critical parameters
- Objective NA and working distance; wavelength (λ) and exposure path.
- Laser power at sample (mW), repetition rate (frep), pulse width.
- Writing/scan speed (µm/s), slicing/hatching, layer spacing (∆z).
- Resin ID, batch, temperature; cleaning and post-cure method.
Quick calibration (Curing Rate Table)
Use when time is limited. Fix your target writing speed and sweep laser power at the sample to populate a Curing Rate Table (e.g., cured thickness/feature continuity vs. power).
- Objective: determine the optimum laser power at your chosen writing speed for the selected resin and your printer’s specifications.
- Outcome: by analyzing the table, the power/intensity threshold and the dynamic exposure range can be readily identified.
- Record: qualitative result (under/optimal/over), minimum continuous line, dimensional error (%), surface quality.
Note. If you can, follow up with the full matrix below to validate limits and expand the process window.
Full calibration (Power–Speed matrix)
Note: To obtain a full calibration, measure responses for (i) laser power at fixed writing/scan speeds and (ii) writing/scan speed at fixed laser powers. The resulting power–speed table delineates the minimum and maximum viable writing/scan speeds per power level and records resolution and dimensional accuracy for each calibration point.
- Design the grid. Select 5–8 power levels and 5–8 writing speeds covering your expected range.
- Acquire data. Print standardized test features (lines, lattices, pillars) at each grid point with consistent focus and environment.
-
Measure. For each point, document:
- Continuity (passes/fails), minimum resolvable line (µm).
- Dimensional accuracy (% error vs. CAD) and edge fidelity.
- Surface/ridge quality (qualitative score), defects (burn/voids).
-
Interpretation. Compute a simple dose proxy
P/v(nJ/µm). Map “under → optimal → over” to identify the stable operating window.
- Objective (NA), λ, resin ID & batch, temperature.
- Power at sample (mW), frep, pulse width (if available).
- Writing speed (µm/s), slicing/hatching, ∆z.
- Cleaning/post-cure method and times.
- Resolution (µm) and dimensional accuracy (%) at each grid point.
Glossary — Writing vs. Scan speed
Writing speed: effective speed while exposing (laser ON) along the toolpath; use this value for P/v and pulse spacing: Δx = vwrite / frep.
Scan speed: motion speed of galvos/stages (may include non-exposing moves, jumps, acceleration ramps). Report writing speed for calibration.
Acceptance guidelines (suggested, adapt to application)
- Dimensional accuracy: ≤ ±2–3% at target feature sizes (50–200 µm typical for process sign-off).
- Resolution: minimum continuous line meets application spec; no scorching or voids.
- Stability: ≥ 3 consecutive prints within tolerance at the selected recipe.
Safety & process notes
- Follow laser safety practices for your system class; use appropriate enclosures and PPE.
- Use only approved cleaners and post-cure conditions for the selected 2PP resin.
For general guidance, see: Instructions for Use "IFU" for 2PP printers